Test Operation - Samsung MIM-E03A Installation Manual

Table of Contents

Advertisement

Setting option switches and function of keys
• Code 40✴✴ : User's options for heating devices including internal backup heater and external boiler
401✴ : Space/DHW heating priority and control variables
402✴ : Backup/Booster heater priority and control variables
403✴ : Additional backup boiler operating variables
• Code 50✴✴ : User's options for extra functions
501✴ : New target temperatures of each mode by "Outgoing" hot key of remote controller
5021 : Temperature difference between before & after values in "Economic" DHW mode
503✴ : Time-division multi(TDM) variables for combining operation b/w A2A and A2W
Field Setting Value
Main Menu &
Sub Menu Function
Description
Code
Heating/DHW Priority
Outdoor Temp for Priority
Heat Pump
Heating Off
Overshoot
Application
Heating Code
BUH/BSH Priority
40✴✴
Backup Heater
For back-up use only
Threshold Temp
Application
Backup Boiler
Boiler Priority
Threshold Temp
Water Out Temp for Cooling
Room Temp for Cooling
Water Out Temp for Heating
Room Temp for Heating
Outing
Auto Cooling WL1 Temp
Auto Cooling WL2 Temp
Auto Heating WL1 Temp
Others Code
Auto Heating WL2 Temp
50✴✴
Target Tank Temp
DHW Saving Mode
Temp Difference
A2A Max Operation Time
TDM Variable
A2W Min Operation Time
Application
Power Peak Control
Select forced off parts
Using input voltage
• Code 5042
[D-00]
Compressor
0 (Default)
Forced off
1
Forced off
2
Forced off
3
Forced off
26
Sub Code Default
Min
Max
Step
Unit
0(DHW)
0
1(Heating)
-
-
✴✴11
✴✴12
0
-15
20
1
˚C
25
14
35
1
˚C
✴✴13
✴✴14
2
1
4
1
˚C
1(On)
0(Off)
1
-
-
✴✴21
✴✴22
0(Both)
0
2(BSH)
1
-
1(On)
0(Off)
1
-
-
✴✴23
✴✴24
0
-15
35
1
˚C
✴✴31
0(No)
0
1(Yes)
-
-
0(Off)
0
1(On)
-
-
✴✴32
✴✴33
-15
-20
5
1
˚C
25
5
25
1
˚C
✴✴11
✴✴12
30
18
30
1
˚C
25
15
55
1
˚C
✴✴13
✴✴14
16
16
30
1
˚C
25
5
25
1
˚C
✴✴15
✴✴16
25
5
25
1
˚C
15
15
55
1
˚C
✴✴17
✴✴18
15
15
55
1
˚C
30
30
70
1
˚C
✴✴19
✴✴21
5
0
40
1
˚C
30
5
60
5
min
✴✴31
✴✴32
3
0
10
1
min
0(No)
0
1(Yes)
-
-
✴✴41
✴✴42
1
0
3
-
-
1(High)
0(Low)
1
-
-
✴✴43
Back up heater
Booster heater
Forced off
Forced off
Forced off
Permitted
Permitted
Forced off
Permitted
Permitted

Test operation

Picture
Mode
For checking sensor
Cancel
Mode
For checking sensor
Cancel
Explanation
1. Commissioning mode
f For active
f
- Commissioning mode can be implemented regardless
of communication error without outdoor installation.
- The mode will be activated after change to DIP#5 "ON"
or resetting power
- Allowed by Keys input for Heating/How water over for
3sec
f For inactive
f
- Cancel key input over for 3 sec. basic functions of each
keys are not available for commissioning (Inactive : all
heating loads is restored to default)
2. Installation / Checks
- Key #1 ~ #8 : Pump, Backup Heater 1st/2nd control,
Booster Heater, Backup Boiler, 3-way valve(for 2-way
valve, how water ↔ heating/cooling), 2-way valve
#1(Thermostat #1 for Zone #1), 2-way valve #2
(Thermostat #2 for Zone #2)
- Icons displayed and contact output will be provided
when button input by wired remote controller (3way
valve for how water (key#6) come to default condition
(room direction) other keys come to default (OFF)
- If the input of pump (#1) not performed than backup
heater (#2, #3), "Not available" signal will be pop up.
- 3way valve (key#6) will not go into "ON" simultaneously
with zone control and 2 way valve for cooling. While
input of "ON" for something be progressed, if another
input signal be putted, "Not available" signal will be pop
up. Prohibited for getting to "ON" between 2 way valves
(Zone #1 = 2-1, Zone #2 = 2-2)
- Each key can be allowed to change in condition of
initial default (one time), if users want to do re-input
in case of wrong operation, all loads contacts will be
restored to default (FF) and "Not available" will be
displayed over one time input.
- The key of "VIEW" always be allowed for input. Every
time the key be pushed, values of Water In, Water Out1
(Heat Exchanger Out), Water Out2 (Backup Heater
Out), Tank, Room will be displayed in order. If no input
additionally for 5 sec, it will be restored to previous
condition.
27