Wiring Works - Samsung MIM-E03A Installation Manual

Table of Contents

Advertisement

Wiring works

Overall schematics
Main Power
2way Valve
Relay
(Zone2)
Booster Heater
2way Valve
(Zone1)
Boiler
2way Valve
Back up
(DHW)
heater1
Back up
heater2
Pump
8
Flow S/W
Outdoor Unit
Temp Sensor
Solar
Wired Room
Wired Room
Thermostat1
Thermostat1
Power and communication with outdoor unit
Power Wire
Connecting the power wire
1. Connect 'Live' and 'Neutral' power line with 'pin #1' and 'pin #2' in TB-A.
2. Connect 'Protective Earth' line with 'Earth screw' in case.
Recommended wire specification
Load
Power Supply
Do NOT use Heater
(Water Pump, Valve,
Wired RMC)
1Ø, 220-240V, 50Hz
Use Booster Heater
(3kw)
Connecting the communication wire
f Connect 'outdoor unit's F1&F2' with 'control kit's F1&F2 in TB-C' by 2 core cable.
f
Control Kit
Communication Wire
Power Cable
Max. Length
Type GL
mm
, wires
m
2
1.5 / 3
L < 10m
10~
2.5 / 3
10m < L
10~
4.0 / 3
L < 10m
6.0 / 3
10m < L
Outdoor Unit
(at Control Plate)
A
30
30
9