Wiring works
Solar Pump
Connecting solar pump
1. Connect 'Solar pump power line' with 'pin #25, 26' in TB-B.
f If pin#25, 26 get AC230V, Control Kit will aware Solar Panel supply heat to DHW tank.)
f
Maximum Consumption Power
Each port use under 10mA
NOTE
Specification table
Part
Connection pin
Connection load
Output
Condition for operation
22
Solar Panel
Specification
#25 : Output Power N
#26 : Detecting Power L
Direct connect from solar pump (AC230V)
AC 230V (MAX 10mA)
(NOT Define)

Setting option switches and function of keys

DIP switch setting
S/W
OFF (Default)
S/W #1
Heating and cooling
S/W #3
Target temp. : Water outlet temp.
S/W #3
Air sensor in remote controller
S/W #4
Master Remote controller
Error detection when outdoor communication is
S/W #5
broken
S/W #6
Normal operation
S/W #7
No use
S/W #8
No use
ON
Heating only
Target temp. : Indoor temp.
External air sensor
Slave Remote controller
Error non-detection , For Commissioning /
Emergency
Emergency
No use
No use