Siemens SINAUT MD720-3 System Manual page 50

Gprs/gsm-modem
Hide thumbs Also See for SINAUT MD720-3:
Table of Contents

Advertisement

SINAUT MD720-3 in Terminal Mode
AT+CMGS
Sending SMS
Test
Command:
AT+CMGS=?
Response:
OK
Executive command
In text modus (+CMGF=1):
Command:
+CMGS=<da>,<toda><CR>
> text is entered<ctrl-Z/ESC>
In PDU mode (+CMGF=0):
AT+CMGS=<length><CR> enter PDU <ctrl-Z/ESC>
In text mode (+CMGF=1) and successful sending:
Response:
+CMGS: 0
If sending fails:
+CMS ERROR: <err>
In PDU mode (+CMGF=0) and successful sending:
+CMGS: <mr>[,<ackpdu>]
OK
Parameter:
<da>:
Enter phonenumber with " "
<toda>:
145:
129:
<mr>:
TP-Message-Reference in integer format
<ackpdu>
RP-User-Data element of RP-ACK PDU; format is same as for <pdu> in case of SMS, but
without 3G TS 24.011 [6] SC address field and parameter shall be bounded by double
quote characters like a normal string type parameter
<length>
Integer type value indicating in the text mode (+CMGF=1) the length of the message body
<data> > (or <cdata>) in characters; or in PDU mode (+CMGF=0), the length of the actual
TP data unit in octets (i.e. the RP layer SMSC address octets are not counted in the
length)
Notice:
The device shall send a four character sequence <CR><LF><greater_than><space>
(IRA 13, 10, 62, 32) after command line is terminated with <CR>; after that PDU can
be given from application to the device
the DCD signal shall be in ON state while PDU is given
the echoing of given characters back from the device is controlled by ATE echo
command
the PDU shall be hexadecimal format (similarly as specified for <pdu>) and given in
one line; the device converts this coding into the actual octets of PDU
when the length octet of the SMSC address (given in the PDU) equals zero, the
SMSC address set with command Service Centre Address +CSCA is used; in this
case the SMSC Type-of-Address octet shall not be present in the PDU, i.e. TPDU
starts right after SMSC length octet
sending can be cancelled by giving <ESC> character (IRA 27)
<ctrl-Z> (IRA 26) must be used to indicate the ending of PDU
50
Enter phone number incl. country code, e.g. +49xxxxx for Germany
Enter phone number without country code
SINAUT MD720-3
C79000-G8976-C211

Hide quick links:

Advertisement

Table of Contents
loading