Siemens SINAUT MD720-3 System Manual page 31

Gprs/gsm-modem
Hide thumbs Also See for SINAUT MD720-3:
Table of Contents

Advertisement

ATD
Mobile originated Call to dial a number
Executive command
Command:
ATD[<n>]
Response:
The connection cannot be established:
NO DIALTONE
BUSY
NO CARRIER
NO ANSWER
Data connection successfully connected:
CONNECT[<text>]
<n>:
Parameter:
String of dialing digits and optionally V.25ter modifiers (dialing digits): 0-9, * , #, +, A, B, C
Notice:
-
ATE
Local Echo On/Off
Executive command
Command:
ATE[<value>]
Response:
OK
Parameter:
<value>:
0 Local Echo off
1 Local Echo on <Default>
Notice:
This setting determines whether or not the device echoes characters received from
application during command state
ATH
Disconnect existing connection
Executive command
Command:
ATH
Response:
OK
Parameter:
-
Notice:
On this command, all calls in progress are ended.
If a call is in progress, it is necessary to switch into the command phase by +++ before
entering commands.
SINAUT MD720-3
C79000-G8976-C211
SINAUT MD720-3 in Terminal Mode
31

Hide quick links:

Advertisement

Table of Contents
loading