SINAUT MD720-3 in Terminal Mode
ATI
Request identification information
Read command
Command:
ATI[<value>]
Response:
<text> (depends on <value>)
OK
Parameter:
<value>:
none:
0:
1:
3:
Notice:
<text> may take more than one line
ATO
Switch from command mode to data mode
Executive command
Command:
ATO[n]
Device returns to data mode from command mode:
Response:
CONNECT <text>
If connection is not successfully resumed
NO CARRIER
Parameter:
<n>:
0
Notice:
ATO corresponds to the +++ escape sequence.
ATQ
Set result code presentation mode
Executive command
ATQ[<n>]
Command:
Response:
OK
Nothing (if <n> = 1)
<n>:
Parameter:
0:
1:
Notice:
Specifies whether or not the device transmits any result code to the application.
Information text transmitted in response is not affected by this setting.
ATS0?
Shows Automatic answering settings
Read command
ATS0?
Command:
Response:
<n>
OK
Parameter:
See ATS0=<n>
Notice:
-