'F' (Factory default)
Parameters:
None
Format:
'F'
Output:
'@'
Purpose:
To set KDC100 internal options and flag to the factory default setting
[Note]
The factory default settings are:
All symbologies are enabled
All options are disabled except
− UPCE_ReturnCheckDigit
− UPCA_ReturnCheckDigit
− EAN8_ReturnCheckDigit
− EAN13_ReturnCheckDigit
Minimum barcode length is set to 4
Time-out is set to 2 seconds
Security Level is set to 2
Select wide scan angle
Sleep timeout is set to 5 seconds
Wedge and Store. Send the scanned barcode to HOST and save into flash
Data format is barcode only
KDC100 Programming Manual
15