'U' (Set data process mode)

Parameters:
0, 1, 2, 3 or 4
Format:
"U<value>#", where <value> is between 0 and 4, and # means the end of <value>
0: KDC100 doesn't store scanned barcode in the memory and just transmits it to the
host
1: KDC100 stores scanned data in the memory and transmits it to the host
2: KDC100 stores scanned data in the memory but doesn't transmit it to the host
3: KDC100 stores scanned data in the memory only if it succeeds to send read
barcode to the host
4: KDC100 stores scanned date in the memory only if it fails to send read barcode to
the host
Output:
'!' – invalid parameter
'@' – all other times
Purpose:
To set the data process mode of KDC100
value
Character
0
1
2
3
4
KDC100 Programming Manual
Hex No.
"0"
"1"
"2"
"3"
"4"
56
30
31
32
33
34