No.
Part name
(
Cross flow
<Caution at reassembling>
fan
a) At assembling work of the bearing base, check
b) To incorporate the fan motor, remove the fan
Lue lisää nettisivuiltamme: www.ilmalämpöpumput.com
Procedures
that the drain pipe is surely incorporated
in the back body.
(Otherwise, water leak is caused.)
Drain pipe
motor rubber (at shaft core side), incorporate the
motor into the position in the following figure,
and then install the fan motor.
• Install the cross flow fan so that the right end
of the 1st joint from the right of the cross flow
fan is set keeping 70.5mm from wall of rear
plate of the main unit.
• Holding the set screw, install the cross flow
fan so that U-groove of the fan motor comes to
the mounting hole of the set screw.
U groove
• Perform positioning of the fan motor as fol-
lows:
• When assembling the fan motor, the fan motor
must be installed in such a way that the fan
motor leads will be taken out is positioned at
the bottom front.
• After assembling the two hooking claws of the
motor band (right) into the main body, position
the fan motor, insert it, and then secure the
motor band (right) using the two fixing screws.
– 92 –