Download Print this page

Toshiba RAS-B10EKVP-E Service Manual page 86

Split type
Hide thumbs Also See for RAS-B10EKVP-E:

Advertisement

Ilmalämpöpumppujen myynti, huolto ja asennus: Jäähdytinpalvelu RefGroup Oy.
No.
Part name
"
1) Follow to the procedure in the item !.
High voltage
generator
2) Remove the drain guide.
3) To remove the air ionizer from the back body,
4) Disconnect the connectors of the high-voltage
5) Remove the fixing screw which secures the high
Lue lisää nettisivuiltamme: www.ilmalämpöpumput.com
Procedures
pull it toward you while pressing down on its left
and right claws. Disconnect the two leads
(black) connected to the air ionizer from where
they are fitted into the other components.
(Caution: do not remove the Faston.)
generator, and disconnect the four leads from
where they are fitted into the other components.
voltage generator, and remove the high voltage
generator from the evaporator.
– 86 –
Remarks
Connector
Drain
guide
Air ionizer
Push the
claw here
Push the
claw here
Pull here
Screw