No.
Part name
#
Electric parts
1) Follow the procedure up to 4) in
box assembly
2) Remove screw of earth lead attached to the end
3) Remove the lead wire cover, and remove
4) Pull out TC sensor from sensor holder of the
5) Disengage the two claws at the top of the
6) Remove the fixing screw that secures the
<How to assemble the electric parts assembly>
1) Hook the top part of the electric parts box
2) Secure the grounding wire using the fixing screw.
Lue lisää nettisivuiltamme: www.ilmalämpöpumput.com
Procedures
plate of the evaporator.
connector (5P) for the fan motor and connector
(5P) for the louver motor from the electric parts
box assembly.
evaporator.
display unit. (They can be easily disengaged by
pressing the drain pan above the claws and at
the same time pulling the display unit toward
you.)
electric parts box assembly, and remove the
assembly.
assembly onto the claws on the back body, and
secure it using the fixing screw. Now attach the
display unit. Connect the connectors for the fan
motor and louver motor.
Insert the TC sensor into the sensor holder.
* Be absolutely sure to loop the grounding wire
and TC sensor leads once at the bottom.
"
above.
– 88 –
Remarks
Lead wire
cover
TC sensor
Fan motor
connector
Louver moter
connector
Screw
Fixing screw
Make absolutely sure that
the leads form a loop
Push the
drain pan
Pull the display
unit toward you