11-4. Self-Diagnosis by Remote Controller (Check Code)
(1) If the indicators light as shown B to E in Table 11-3-1, excute the self-diagnosis by the remote controller.
(2) When the remote controller is set to the service mode, the indoor controller diagnoses the operation condition
and indicate the information of the self-diagnosis on the display of the remote controller with the check
codes. If a fault is detected, all indicators on the indoor unit will flash at 5Hz and it will beep for 10 seconds
(Pi, Pi, Pi ... ). The TIMER indicator usually flashes (5Hz) during self-diagnosis.
11-4-1. How to Use Remote Controller in Service Mode
PURE
AUTO
TEMP
MODE
PRESET
HiPOWER
ECO
MEMO
1 . 3 . 5 . 9H
SWING
FIX
FAN
SLEEP
CLR
SET
ON
OFF
CLOCK
RESET
CHECK
Alphanumeric characters are
used for the check codes.
is 5.
is A.
is C.
Lue lisää nettisivuiltamme: www.ilmalämpöpumput.com
1
2
is 6.
is B.
3
is D.
4
Push [CHECK] button with a tip of pencil to set the
remote controller to the service mode.
• "
" is indicated on the display of the remote
controller.
Push [ON
] or [OFF
If there is no fault with a code, the indoor unit will beep
once (Pi) and the display of the remote controller will
change as follows :
• The TIMER indicator of the indoor unit flashes continuously.
(5 times per 1 sec.)
• Check the unit with all 52 check codes (
as shown in Table-10-4-1.
• Push [ON
] or [OFF
code backward.
If there is a fault, the indoor unit will beep for 10
seconds (Pi, Pi, Pi...).
Note the check code on the display of the remote
controller.
• 2-digits alphanumeric will be indicated on the display.
• All indicators on the indoor unit will flash.
(5 times per 1 sec.)
Push [START/STOP] button to release the service mode.
• The display of the remote controller returns to as it
was before service mode was engaged.
Time shotening method.
1. Push SET button while pushing CHECK button.
2. Push [START/STOP] button.
Fig. 11-4-1