Download Print this page

Toshiba RAS-B10EKVP-E Service Manual page 91

Split type
Hide thumbs Also See for RAS-B10EKVP-E:

Advertisement

Ilmalämpöpumppujen myynti, huolto ja asennus: Jäähdytinpalvelu RefGroup Oy.
No.
Part name
'
Fan motor
1) Follow to the procedure in the item
2) Loosen the set screw of the cross flow fan.
3) Remove two fixing screws of the motor band
4) Pull the fan motor outward.
In assembling work, install the fan motor as
follows.
• When assembling the fan motor, the fan motor
must be installed in such a way that the fan
motor leads will be taken out is positioned at the
bottom front.
• After assembling the two hooking claws of the
motor band (right) into the main body, position the
fan motor, insert it, and then secure the motor
band (right) using the two fixing screws.
(
Cross flow
1) Follow to the procedure in the item
fan
2) Remove the heat exchanger fixing holder by
3) Loosen the set screw of the cross flow fan.
4) Lift the left side of the heat exchanger, and pull
Lue lisää nettisivuiltamme: www.ilmalämpöpumput.com
Procedures
(Right), and then remove the motor band (Right).
Fan motor leads
removing the two fixing screws used to secure
it.
out the cross flow fan.
#
.
Secure using the
fixing screw
Screw
Motor band (Right)
Screw
Secure using the
fixing screw
&
.
– 91 –
Remarks
Set screw
Raise the
left side
Pull out here