To Remove Water Pump And Bottle Complete - Panasonic WH-SDC12F6E5 Service Manual

Hide thumbs Also See for WH-SDC12F6E5:
Table of Contents

Advertisement

During reinstall Air Purge Valve.

18.8 To Remove Water Pump and Bottle Complete

2. Loosen the nut.
When reinstall the water pipe, use grease or water at the joining.
Make sure plug is fully close
in clockwise direction.
Apply some water based
grease on packing surface
before fix with shut off valve.
Packing
3. Remove 2 retaining ring
then pull out the Water Pump.
Water Pump
1. Disconnect CN-PUMP2
from Electronic Controller.