11.3.4.1
Wire Stripping and Connecting Requirement
Wire stripping
No loose strand
when insert
Tank Sensor Resistance Vs Temperature
16000
14000
12000
10000
8000
6000
4000
2000
Graph 5.1: Tank sensor characteristic
11.3.4.2
Connecting Requirement
The equipment's power supply 1 complies with IEC/EN 61000-3-12 provided that the short-circuit power S
greater than or equal to 1200 kW (for WH-SDC12F6E5/UD12FE5) at the interface point between the user's
supply and the public system. It is the responsibility of the installer or user of the equipment to ensure, by
consultation with the distribution network operator if necessary, that the equipment is connected only to a supply
with a short-circuit power S
The equipment's power supply 1 shall be connected to a suitable supply network, having service current capacity
≥ 100A per phase. Please liaise with supply authority to ensure that the service current capacity at the interface
point is sufficient for the installation of the equipment.
The equipment's power supply 2 complies with IEC/EN 61000-3-12.
The equipment's power supply 2 shall be connected to a suitable supply network, with the following maximum
permissible system impedance Z
ensure that power supply 2 is connected to a supply of the impedance or less.
Detail A
Indoor/outdoor
connecting
terminal board
5mm or
more
(gap between
wires)
0
-30
-20
-10
0
10
20
˚C
greater than or equal to 1200 kW.
sc
at the interface of the point: 0.271 Ω. Please liaise with supply authority to
max
Solar Pump Station Cable
(Optional)
Solar Three-way Valve
Cable (Optional)
External Control Cable
(Optional)
Tank Sensor Cable
(Optional)
Tank OLP Cable (Optional)
Room Thermostat Cable
(Optional)
Booster Heater Cord
(Optional)
Earth wire must be longer
than other cables for safety
reasons.
Three-way Valve Cable
(Optional)
Two-way Valve Cable
(Optional)
Conductor
fully insert
ACCEPT
Remove this
External Controller
jumper if External
Controller
(Optional) is
connected to the
indoor unit
30
Diagram 5.2: External Controller connecting
43
Conductor
Conductor not
over insert
fully insert
PROHIBITED
PROHIBITED
Switch (ON/OFF)
Terminal
17
18
diagram
is
sc