12 - START-UP AND OPERATION

�esidence Condens wall-mounted condensation boiler designed
for the production of heating and domestic hot water (for IS models
if connected to an external water tank).
The control panel (Fig. 1) contains the main boiler control and ma-
nagement functions.

12.1 - Switching on the appliance

Switch on the boiler as follows:
� open the gas tap under the boiler by turning it anti�clockwise
� turn on the general switch of the system and then, turn the fun-
ction selector to summer
the chosen operating mode.
After being powered, the boiler begins an automatic vent cycle la-
sting approximately 2 minutes (for KIS models) and 12 minutes
(for IS models).
During this phase the two digits light up alternatively (fig. 3).
To cut off the automatic bleed cycle unscrew screws A, remove
instrument panel � and press the CO combustion analysis button
(C) (fig. 4), this �ob may be done by qualified personnel only
For KIS models:
SUMMER (
): with the selector in this position, �ust the domestic
hot water function is activated. The display alternatively indicates
the temperature of the domestic hot water and the preheating sta-
tus (P0 not activated, P1 activated) (fig.5)
WINTER (
): with the selector in this position, the heating water
and domestic hot water functions are activated. The display alter-
natively indicates the delivery temperature of the heating water or
the domestic hot water depending on current demand (fig. 5) and
the pre-heating status (P0 not activated, P1 activated).

ON-OFF PRE-HEATING FUNCTION (

ting function is activated which keeps the water in the domestic hot
water exchanger hot in order to reduce waiting times.
The pre-heating function can be activated or disactivated (P0 not
activated � P1 activated) by turning the selector to this position.
The function works both in winter and summer. Turn the function
selector to the required position (summer, winter or OFF) after
completing the operation.
For IS models:
SUMMER (
), only with the external water tank connected):
with the selector in this position the traditional domestic hot water
function provided by the water tank is activated. The display indi-
cates the delivery temperature.
WINTER (
): with the selector in this position, the boiler produ-
ces hot water for heating and, if connected to an external water
tank, it provides water to it to allow it to prepare domestic hot water.
The display indicates the delivery temperature of the heating water
(fig. 5).

Adjusting heating water temperature

To ad�ust the heating water temperature turn the knob marked
(fig. 6) clockwise to increase and anticlockwise to decrease.
When turning the knob, the required temperature automatically ap-
pears on the digital display.
Depending on the type of system, it is possible to pre�select
the suitable temperature range:
� standard systems 40�80°C
� floor systems 20�45°C.
For further details, consult the "�oiler configuration" section.
Adjusting heating water temperature with an external probe
connected
When an external probe is connected, the value of the delivery tem-
perature is automatically chosen by the system which rapidly ad�usts
ambient temperature to the changes in external temperature.
To increase or decrease the temperature with respect to the value
automatically calculated by the electronic board, turn the heating
water selector (fig. 6) clockwise to increase and anticlockwise to
decrease.
Ad�ustment settings range from comfort levels � 5 to + 5 which are
indicated on the digital display when the knob is turned.
12
or winter
(fig. 2) depending on
) (fig. 2): The prehea-
1
2
4
5
1 Domestic hot water temperature selector
2 Digital display
3 Heating water temperature selector
4 Only KIS model: "Pre�heating" function
keeps the water in the domestic hot water exchanger hot in order to
reduce waiting times.
5 "Winter" function
6 "OFF/RESET" function
7 "Summer" function
8 Function selector
* For IS models: the parts of manual referring to the domestic hot water
circuit should only be considered if a water tank is installed, case C
(accessory available on request)
SUMMER
WINTER
A
3
7
6
8
*
: is also activated which
ON-OFF
PRE-HEATING
FUNCTION
C
Fig. 1
Fig. 2
Fig. 3
Fig. 4

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Residence condens 35 kis eResidence condens 20 is

Table of Contents