Beretta MYNUTE GREEN E Installer And User Manual page 20

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 5
ENGLISH
DESCRIPTION
Electric power
Category
Country of destination
Power supply voltage
Degree of Protection
Pressure drops on flue with burner on
Pressure drops on flue with burner off
Heating operation
Pressure - maximum temperature
Minimum pressure for standard operation
Selection field of heating water temperature
Pump: maximum head available
for system capacity
Membrane expansion tank
Expansion tank pre-charge
Gas pressure
Methane gas nominal pressure (G20)
LPG liquid gas nominal pressure (G31)
Hydraulic connections
Heating input - output
Water tank delivery - output
Gas input
Boiler dimensions
Height
Width
Depth of housing
Boiler weight
Flow rate (G20)
Air capacity
Flue gas capacity
Mass flow of flue gas (max-min)
Flow rate (G31)
Air capacity
Flue gas capacity
Mass flow of flue gas (max-min)
Fan performance
Residual head of boiler without pipes
Residual head of concentric pipes 0,85 m
Residual head of separate pipes 0,5 m
Concentric flue gas discharge pipes
Diameter
Maximum length
Drop due to insertion of a 45°/90° bend
Hole in wall (diameter)
Concentric flue gas discharge pipes
Diameter
Maximum length
Drop due to insertion of a 45°/90° bend
Hole in wall (diameter)
Separate flue gas discharge pipes
Diameter
Maximum length
Losses for a 45°/90° bend
Installation B23P–B53P
Diameter
Maximum length of drainage pipe
NOx class
Emission values at max. and min. rate of gas G20*
Maximum - Minimum
CO s.a. less than
CO
2
NOx s.a. lower than
Flue gas temperature
* Check performed with concentric pipe ø 60-100, length 0,85m - water temperature 80-60°C
20
Mynute Green 12 R.S.I. E
W
110
II2H3P
-
V - Hz
230 - 50
IP
X5D
%
1,57
%
0,15
bar
3
bar
0,25 - 0,45
°C
20/45 - 40/80
mbar
240
l/h
1.000
l
8
bar
1
mbar
20
mbar
37
Ø
3/4"
Ø
3/4"
Ø
3/4"
mm
780
mm
400
mm
358
kg
36
Nm
h
14,994
3/
Nm
/h
16,197
3
gr/s
5,435 - 1,074
Nm
h
15,113
3/
Nm
/h
16,040
3
gr/s
5,654 - 1,574
Pa
90
Pa
45
Pa
60
mm
60-100
m
7,85
m
1,3/1,6
mm
105
mm
80-125
m
14,85
m
1/1,5
mm
130
mm
80
m
60+60
m
1/1,5
mm
80
m
90
5
ppm
150 - 15
%
9,0 - 9,5
ppm
35 - 20
°C
65 - 58
Mynute Green 25 R.S.I. E
Mynute Green 35 R.S.I. E
123
II2H3P
-
230 - 50
X5D
1,73
0,11
3
0,25 - 0,45
20/45 - 40/80
300
1.000
8
1
20
37
3/4"
3/4"
3/4"
780
400
358
37
31,237
33,744
11,32 - 2,58
31,485
33,416
11,78 - 2,70
180
45
150
60-100
7,85
1,3/1,6
105
80-125
14,85
1/1,5
130
80
36+36
1/1,5
80
60
5
145 - 45
9,0 - 9,5
35 - 30
79 - 57
148
II2H3P
-
230 - 50
X5D
2,53
0,13
3
0,25 - 0,45
20/45 - 40/80
300
1.000
10
1
20
37
3/4"
3/4"
3/4"
780
450
358
42
43,090
46,561
15,614 - 2,996
43,945
45,286
15,288 - 2,944
140
60
122
60-100
7,85
1,3/1,6
105
80-125
14,85
1/1,5
130
80
26+26
1/1,5
80
40
5
160 - 35
9,0 - 9,5
30 - 35
78 - 61

Advertisement

Table of Contents
loading

Table of Contents