Specifications; Environmental Specifications; Mechanical Specifications; Power Supply Specifications - HP hpe proliant dl20 gen9 User Manual

Table of Contents

Advertisement

Specifications

Environmental specifications

Specification
Temperature range*
Operating
Nonoperating
Relative humidity
(noncondensing)
Operating, maximum wet bulb
temperature of 28°C (82.4°F)
Nonoperating, maximum wet
bulb temperature of 38.7°C
(101.7°F)
* All temperature ratings shown are for sea level. An altitude derating of 1° C per 304.8 m (1.8° F per 1,000 ft) to 3048
m (10,000 ft) is applicable. No direct sunlight allowed.

Mechanical specifications

Dimension
Height*
Depth*
Width*
Weight (full load, approximate values)
Maximum
Minimum
* These dimensions apply to all server models.

Power supply specifications

Depending on the installed options and/or the regional location where the server was purchased, the
server is configured with one of the following power supplies:
HPE DL20 Gen9 290W Non-hot Plug Power Supply
HPE 900-W AC 240VDC Power Input Module (PN 775595-B21)
This is supported when the two-bay HPE 900-W AC 240VDC RPS Power Backplane option (PN
814835-B21) is installed.
These are Entry Level Power Supply products for ProLiant servers. For more information about the power
supply features, specifications, and compatibility, see the Hewlett Packard Enterprise website
(http://www.hpe.com/info/proliant/powersupply).
CAUTION: Check the system and power supply input ratings before powering up the server.
Value
0° C to 40° C (32° F to 104° F)
-30° C to 65° C (-22° F to 149° F)
10% to 90%
0% to 95%
Value
4.32 cm (1.70 in)
38.22 cm (15.05 in)
43.46 cm (17.11 in)
8.7 kg (19.14 lb)
6.9 kg (15.09 lb)