Installing Hardware Options; Installing The Server Into The Rack - HP hpe proliant dl20 gen9 User Manual

Table of Contents

Advertisement

T-10/T-15 Torx screwdriver
Hardware options

Installing hardware options

Install any hardware options before initializing the server. For options installation information, refer to the
option documentation. For server-specific information, refer to "Hardware options installation (on page
36)."

Installing the server into the rack

To install the server into a rack with square, round, or threaded holes, refer to the instructions that ship
with the rack hardware kit.
Follow the server-specific instructions on the website to install the rack brackets.
Use the following information when connecting peripheral cables and power cords to the server.
WARNING: This server is very heavy. To reduce the risk of personal injury or damage to the
equipment:
• Observe local occupational health and safety requirements and guidelines for manual
material handling.
• Get help to lift and stabilize the product during installation or removal, especially when the
product is not fastened to the rails. Hewlett Packard Enterprise recommends that a
minimum of two people are required for all rack server installations. A third person may be
required to help align the server if the server is installed higher than chest level.
• Use caution when installing the server in or removing the server from the rack; it is unstable
when not fastened to the rails.
CAUTION: Always plan the rack installation so that the heaviest item is on the bottom of the
rack. Install the heaviest item first, and continue to populate the rack from the bottom to the top.
To install the server in a Hewlett Packard Enterprise, Compaq-branded, Telco, or a third-party rack:
Install the server into the rack. See the documentation that ships with the Quick Deploy Rail System.
1.
Connect peripheral devices to the server. For information on identifying connectors, see "Rear panel
2.
components (on page 9)."
WARNING: To reduce the risk of electric shock, fire, or damage to the equipment, do not plug
telephone or telecommunications connectors into RJ-45 connectors.
For a server using a non-hot-plug power supply: To prevent the accidental disconnection of the
3.
power cord when sliding the server into and from the rack, secure the power cord through the strain
relief clip:
Setup 30

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents