Drive Options; Removing A Drive Blank - HP proliant ml350 gen9 User Manual

Hide thumbs Also See for proliant ml350 gen9:
Table of Contents

Advertisement

LFF configuration
Install the fan cage.
10.
Install the air baffle (on page 28).
11.
If the server is in a tower configuration, do the following:
12.
Install the access panel
a.
Return the server to an upright position.
b.
Install the bezel.
c.
If the server is in a rack configuration, do the following:
13.
Install the access panel
a.
Slide the server into the rack.
b.
Connect each power cord to the server.
14.
Connect each power cord to the power source.
15.
Press the Power On/Standby button.
16.
The server exits standby mode and applies full power to the system. The system power LED changes
17.
from amber to green.

Drive options

When adding drives to the server, observe the following general guidelines:
The system automatically sets all device numbers.
If only one drive is used, install it in the bay with the lowest device numbering (on page 19).
Drives should be the same capacity to provide the greatest storage space efficiency when drives are
grouped together into the same drive array.

Removing a drive blank

Do one of the following:
1.
("Install the air
baffle" on page 28).
("Install the air
baffle" on page 28).
Hardware options installation 76