REPAIR INSTRUCTIONS
1. Disconnect the appliance from mains.
2. Press simultaneously
3. Connect the appliance to mains.
4. If above steps succeeded the display will show the following message "LOAD TEST MODE"
Using the functions in the Service/test mode.
When the Service/test mode is entered, the following functions can be carried out / checked.
Function selection
1.
Operate Brewing
Heater
2.
Operate Pump
3.
Operate the grinder
4.
Operate Brewing unit
upwards (motor lift)
5.
Operate Brewing unit
down (motor lift)
6.
Operate discharge valve
(EV1)
7.
Operate steam Heater
PUTTING THE APPLIANCE INTO SERVICE/TEST MODE
MENU
OK
and
Coffee buttons.
Action to perform
Push the MENU
button
Push the
button
Push the OK button
Push the On/OFF
button
Push the
button
Push the
button
Push the
button
OFF
ON
Display message
Result of the action
HEATER ON
Close steam knob!!! **
The Brewing heater will be powered, check
power consumption (± 1240 W). *
PUMP ON
If water container is fi lled, placed and steam
knob is closed ** the pump will be powered
(± 40 W).
GRINDER ON
Close steam knob!!! **
Grinder will grind "Beans".
MOTOR UP
If this function will be performed always
be sure the Brewing unit has been installed,
service door is closed & Coffee ground
&
container is in place.
If the brewing unit_up_position M1
has been activated by the Brewing unit
LIMIT SWITCH
the Display will show message LIMIT
UP
SWITCH UP.
MOTOR DOWN
If this function will be performed always
be sure the Brewing unit has been installed,
service door is closed & Coffee ground
&
container is in place.
If the brewing unit_down_position M2
has been activated by the Brewing unit
LIMIT SWITCH
the Display will show message LIMIT
DOWN
SWITCH DOWN.
EV1 ON
Close steam knob!!! **
The 3way discharge valve will be powered.
VAPORIZER ON
You will have to turn the steam knob
fully open, before the steam heater will be
powered! ("message open knob" appears)
check power consumption (± 1 kW). *