Solving Problems Described By Lcd Status Messages - Dell PowerEdge 1900 Systems Owner's Manual

Hide thumbs Also See for PowerEdge 1900 Systems:
Table of Contents

Advertisement

Table 1-4. LCD Status Messages (continued)
Code
Text
Fatal NB Mem CRC One of the connections in the
E2118
Fatal SB Mem CRC One of the connections in the
E2119
I1910
Intrusion
I1911
>3 ERRs Chk Log
I1912
SEL Full
ROMB Batt < 24hr Warns predictively that the RAID
W1228
NOTE:
For the full name of an abbreviation or acronym used in this table, see the "Glossary" on page 161.

Solving Problems Described by LCD Status Messages

When a single message appears on the status LCD, locate the code in Table 1-4 and perform the
suggested corrective action. The code on the LCD can often specify a very precise fault condition that is
easily corrected. For example, if the code
microprocessor is not installed in socket 1.
In contrast, you might be able to determine the problem if multiple related errors occur. For example, if
you receive a series of messages indicating multiple voltage faults, you might determine that the problem
is a failing power supply.
22
About Your System
Causes
Fully Buffered DIMM (
memory subsystem link on the
Northbound side has failed.
FBD memory subsystem link on
the Southbound side has failed.
System cover has been removed.
LCD overflow message.
A maximum of three error
messages can display sequentially
on the LCD. The fourth message
displays as the standard overflow
message.
System Event Log is full of
events, and is unable to log any
more events.
battery has less than 24 hours of
charge left.
E0780
MISSING CPU 1
Corrective Actions
See "Troubleshooting System
FBD)
Memory" on page 116.
See "Troubleshooting System
Memory" on page 116.
Information only.
Check the SEL for details on the
events.
Clear the log by deleting event
entries.
Replace RAID battery. See
"Replacing the SAS RAID
Controller Daughter Card
Battery" on page 95.
appears, you know that a

Advertisement

Table of Contents
loading

Table of Contents