Dell PowerEdge 1900 Systems Owner's Manual page 17

Hide thumbs Also See for PowerEdge 1900 Systems:
Table of Contents

Advertisement

Table 1-4. LCD Status Messages (continued)
Code
Text
E1211
ROMB Batt
E12nn
XX PwrGd
E1229
CPU # VCORE
E122B
0.9V Over
Voltage
E122C
CPU Power Fault
E1310
RPM Fan ##
E1410
CPU # IERR
Causes
RAID battery is either missing,
bad, or unable to recharge due to
thermal issues.
Specified voltage regulator has
failed.
Processor # VCORE voltage
regulator has failed.
0.9 V regulator voltage has
exceeded the allowable voltage
range
A voltage regulator failure was
detected when the processor
regulator(s) was enabled
RPM of specified cooling fan is
out of acceptable operating range.
Specified microprocessor is
reporting a system error.
Corrective Actions
Reseat the RAID battery. See
"Replacing the SAS RAID
Controller Daughter Card
Battery" on page 95, and
"Troubleshooting System Cooling
Problems" on page 115.
See "Getting Help" on page 137.
See "Getting Help" on page 137.
See "Getting Help" on page 137.
See "Getting Help" on page 137.
See "Troubleshooting System
Cooling Problems" on page 115.
See your system's Information
Update Tech Sheet located on
support.dell.com for the most
current system information. If the
problem persists, see "Getting
Help" on page 137.
About Your System
17

Advertisement

Table of Contents
loading

Table of Contents