3. Remove the 2 (C.C.P-TITE SCREW, 3x8, F/ZN-3C) screws that secure the Cover Lens
Frame, and remove the Cover Lens Frame from the Upper Case E.
4. Remove the Photo Interrupterthe, the Cover Lens Guide and the Lamp Lid Latch Spring
from the Cover Lens Frame.
5. Disconnect the SW Cable from the Photo Interrupter.
Lamp Lid Latch Spring
SW Cable
Photo Interrupter
Cover Lens Guide
C A U T I O N
Apply the proper amount of lubricant to the surface indicated by gray shading.
SEIKO EPSON
EMP-S4
Cover Lens Frame
Figure 4-14.
Figure 4-15.
4-17
*Be sure to apply the
lubricant not only when
replacing parts but also
when the Cover Lens does
not slide smoothly. For
details, refer to 4.1.2 Tools
and Equipment