1. COOLING OPERATION

A sensor (room temperature thermistor) built in the indoor unit body will usually perceive
difference or variation between a set temperature and present room temperature, and
controls the operation frequency of the compressor.
* If the room temperature is 2°C higher than a set temperature, the compressor operation
frequency will attain to maximum performance.
* If the room temperature is some degrees lower than a set temperature,
the compressor will be stopped.
* When the room temperature is between +2°C to -2.5°C of the setting temperature,
the compressor frequency is controlled within the range shown in Table1.
However, the maximum frequency is limited in the range shown in Fig.1 based on the indoor
fan mode and the outdoor temperature.
( Table 1 : Compressor frequency range )
AS*G09LTCB
AS*G12LTCB
AS*G14LTCB
When the compressor operates for 30 minutes continuously at over the maximum frequency ,
the maximum frequency is changed from Maximum Frequency
( Fig.1 : Outdoor temperature zone )
Outdoor
temperature drops
A zone
34°C
B zone
30°C
C zone
19°C
D zone
10°C
E zone
0°C
F zone
Minimum
Maximum
frequency
frequency
18rps
76rps
15rps
57rps
12rps
63rps
Outdoor
temperature rises
36°C
32°C
21°C
12°C
2°C
Maximum
frequency
96rps
76rps
91rps
to Maximum Frequency .
( Table 2 : Limit of maximum speed based on outdoor temperature )
Outdoor
temp. zone
A zone
AS*G09LTCB
B zone
C zone
D zone
E zone
F zone
AS*G12LTCB
A zone
B zone
C zone
D zone
E zone
F zone
AS*G14LTCB
A zone
B zone
C zone
D zone
E zone
F zone
01-01
Indoor fan mode
Hi
Me
Lo
Quiet
96rps
61rps
51rps
33rps
96rps
61rps
51rps
33rps
96rps
61rps
51rps
33rps
57rps
42rps
36rps
27rps
57rps
42rps
36rps
27rps
57rps
42rps
36rps
27rps
76rps
45rps
37rps
29rps
76rps
45rps
37rps
29rps
76rps
45rps
37rps
26rps
43rps
35rps
26rps
20rps
51rps
37rps
31rps
22rps
51rps
37rps
31rps
22rps
91rps
44rps
34rps
24rps
91rps
44rps
34rps
24rps
72rps
44rps
34rps
24rps
52rps
30rps
21rps
18rps
63rps
34rps
27rps
19rps
63rps
34rps
27rps
19rps