Fujitsu AS*G09LTCB Service Instructions Manual page 15

Split type wall mounted type inverter
Table of Contents

Advertisement

3. SLEEP TIMER
If the sleep is set, the room temperature is monitored and the operation is stopped automatically.
If the operation mode or the set temperature is change after the sleep timer is set, the operation is
continued according to the changed setting of the sleep timer from that time ON.
In the cooling operation mode
When the sleep timer is set, the setting temperature is increased 1°C.
It increases the setting temperature another 1°C after 1 hour.
After that, the setting temperature is not changed and the operation is stopped at the time
of timer setting.
+2°C
+1°C
In the heating operation mode
When the sleep timer is set, the setting temperature is decreased 1°C.
It decreases the setting temperature another 1°C every 30 minutes.
Upon lowering 4°C, the setting temperature is not changed and the operation stops at
the time of timer setting.
Ts
-1°C
-2°C
-3°C
-4°C
4. WEEKLY TIMER
This timer function can set operation times of the each day of the week.
All days can be set together,the weekly timer can be used to repeat the timer setting for all of the days.
ON
Setting day
Set time
Set time
Set temperature rises
( Ts : Set temperature )
Ts
Set
60min
Set temperature lowers
( Ts : Set temperature )
Set
30min 30min 30min
OFF
ON
Setting day
Stop of operation
Stop of operation
OFF
ON
Setting day
01-10
OFF

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

As*g14ltcbAo*g09ltcnAo*g12ltcnAs*g12ltcbAo*g14ltcn

Table of Contents