Outdoor Fan Control - Fujitsu AS*G09LTCB Service Instructions Manual

Split type wall mounted type inverter
Table of Contents

Advertisement

6. OUTDOOR FAN CONTROL

1. Outdoor Fan Motor
Following table shows the type of the outdoor fan motor. The control method is different
between AC motor and DC motor.
( Table 7 : Type of Motor )
AO*G09/ 12/ 14LTCN
2. Fan Speed
( Table 8 : Outdoor fan speed )
AO*G09LTCN
AO*G12LTCN
AO*G14LTCN
Refer to Fig.8
( Fig.8 : Outside air temperature zone selection )
Outside air
temperature rises
21°C
12°C
2°C
* The outdoor fan speed mentioned above depends on the compressor frequency.
(When the compressor frequency increases, the outdoor fan speed also changes to the higher
speed. When the compressor frequency decreases, the outdoor fan speed also changes to the
lower speed.)
* After the defrost control is operated on the heating mode, the fan speed keeps at the higher speed
as table 9 without relating to the compressor frequency.
( Table 9 : Outdoor fan speed after the defrost )
AO*G09LTCN
AO*G12LTCN
AO*G14LTCN
AC Motor
Zone
Cooling
Y
850/ 750/ 670/ 500
Z
850/ 500/ 350
F
330/ 300
G
280/ 230
Y
1050/ 870/ 720/ 590/ 530
Z
870/530/300
F
300/ 250
250/ 200
G
Y
1050/ 870/ 720/ 530
870/ 530/ 300
Z
F
300
250/ 200
G
Outside air
temperature drops
Y zone
19°C
Z zone
10°C
F zone
0°C
G zone
950rpm
1100rpm
1100rpm
DC Motor
950/ 850/ 750/ 670/ 550/ 450
1100/ 870/ 780/ 720/ 590/ 480
1100/ 1000/ 780/ 720/ 590/ 480
01-06
Heating
Dry
760/ 470
530
530
(rpm)

Hide quick links: