C o m m o n E r r o r s
Errors 001 to 405 and 429 to 435 are data errors. This type of error
indicates that incorrect data was sent to the printer, and the printer is
ignoring it. Your System Administrator should correct the packet and send it
back to the printer.
Error
Description/Action
002
Name must be 1 to 8 characters (excluding non-printable control
characters) inside quotes.
005
Supply width is invalid.
018
Code page selection defined in the field must be 0 (Internal), 1
(ANSI), 100 (Macintosh), 101 (Wingdings), 102 (UNICODE), 103
(BIG5 for UNICODE), 104 (GB2312 for UNICODE), 105 (SJIS for
UNICODE), 106 (GB2312), 107 (BIG5), 437 (DOS Page 437),
850 (DOS Page 850), 852 (Latin 2), 855 (Russian), 857
(Turkish), 860 (Portuguese), 1250 (Latin 2), 1251 (Cyrillic), 1252
(Latin 1), 1253 (Greek), 1254 (Turkish), 1255 (Hebrew), 1256
(Arabic), 1257 (Baltic), or 1258 (Vietnamese).
025
Data length is too long.
101
Format referenced by batch not in memory.
400
Invalid character following {.
403
Field separator was not found.
409
Printer memory is full. Delete unnecessary formats or graphics
from memory.
410
Parity mismatch.
411
Framing error (baud rate mismatch).
412
Flow control mismatch.
413
Online receive buffer is full. Check for a flow control problem.
10-8 Operator's Handbook