Inspection and Adjustment of Body back
"0" positioning of the dial gauge
Surface plate
(1) Mount the tool (J18001-1) on the surface plate as above, then set the dial gauge to "0".
(2) From "0" position of (1), turn the index circle in the direction of the arrow so that the needle is on "0.17mm".
(This position is "0" position of D700.)
(3) Measure the body back based on "0" position of the index circle.
"0" positioning of the digital gauge
0.00
ZERO/ABS
ON/OFF
PRESET
TOL.
定盤
Surface plate
(1) Mount the tool (J18001-1) on the surface plate as above, then turn the digital gauge ON and press [ZERO/
ABS] button so that the value becomes "0".
(2) Measure the body back based on "0" position
(3) Subtract "2.17mm" from the measured value. If the value is
it is within standard.
Turn counterclockwise by 0.17 mm.
J18001-1
- A50 ・ D700 -
Turn counterclockwise by 0.17 mm.
"0" position of D700
2.17
ZERO/ABS
ON/OFF
PRESET
TOL.
2.17-2.17 = 0
So this is within
standard.
定盤
Surface plate
"0±0.01 mm / Parallelism: 0.015mm or
INC
VBA22001-R.3754.A
e.g.
less",