Initial Settings (Factory Default Settings); Confirm Data; Version No./ Serial No - Nikon D700 Repair Manual

Hide thumbs Also See for D700:
Table of Contents

Advertisement

It is necessary to calculate the reference values in order to prevent the color temperature fluctuation caused by
the shutter tester or color viewer's changes over time from affecting the results of the shooting image adjustment.
By using the reference body, calculate the reference values once in about every 3 months, when either of the
fluorescent of the color viewer or tool lens (F5.6) or ND filter (ND8X2) is replaced.

(13) Initial settings (Factory default settings)

This restores factory default settings. Select the language and video mode. Because this setting of RP DG-PCB
is blank, be sure to set the initial default setting when the DG-PCB is replaced.
(14) Confirm data  
Saving/restoring of the system fixed values, image register, TFT register, EEPROM1, 2, 3.  
The functions of saving/restoring each data is for sending backup data to Service Planning for analysis, if some
problem occurs.
The System fixed data
The Image register
TFT register
FLASH ROM system area
△(Addition)
Image data storage space is divided into FLASH ROM system area (system fixed value, image register, and
TFT register) and EEPROM system area (EEPROM 1, EEPROM 2, and EEPROM 3). But the data itself is
related with each other in a complicated way, so in case of saving/restoring data, be sure to back up all the data
as a set without fail.

(15) Version No./ Serial No.

RISC firmware version and serial number are indicated. Serial number can be written.
※ Whenever the license sheet is replaced, be sure to input the serial number.
Changed page △× 3
△(Addition)
- A137 ・ D700 -
△(Addition)
EEPROM 1
EEPROM 2
EEPROM 3
EEPROM system area
INC
VBA22001-R.3754.A
August, 19,2008