About this document This document summarizes supplementary information on mounting and electrical instal- lation of the TiM3xx as well as license texts. It is aimed at sufficiently qualified personnel for the purposes of installation and commissioning. Notes on commissioning, configuration and maintenance can be found in the TiM3xx oper- ating instructions.
Page 4
Opening the screws of the TiM3xx housing will invalidate any warranty claims against SICK AG. Repairs may only be performed on the TiM3xx by trained and authorized SICK AG ser- vice personnel. The TiM3xx does not constitute personal protection equipment in sense of the respec- tive applicable safety standards for machines.
Operating principle of the TiM3xx The TiM3xx is an opto-electronic laser scanner that electro-sensitively scans the perimeter of its surroundings at a single plane with the aid of laser beams. The TiM3xx measures its surroundings using two-dimensional polar coordinates based on its measurement origin.
Using several TiM3xx The TiM3xx is designed so that mutual interference of the same types of sensors is very un- likely. To preclude even the slightest of influences on the measuring accuracy, we recom- mend installing the TiM3xx as in the examples below.
Set screw for locking the adapter plate after alignment, 2 x Adapter plate Cheese-head screw M3 x 8 in a 3.2 mm (0.13 in) diameter hole for mounting the TiM3xx to the adapter plate, 2 x 7.3.2 mm diameter hole for mounting the TiM3xx directly on the mounting bracket, 2 x (alterna-...
Page 11
All measures of length in mm Procedure for mounting the TiM3xx 1. Mount the TiM3xx to the adapter plate using the two screws M3 x 8 supplied. For this purpose, insert the screws from below through the hole in the mounting bracket and the hole in the adapter plate.
The cable shield e.g. of the supply line is therefore flush with the metal housing of the TiM3xx. The device can either be grounded via the cable shield or via the two straight plates. If the peripheral devices also have metal housing and if the cable shields also flush with their housing, it is assumed that all devices involved in installation have the same ground potential.
Page 18
This prevents any equalization currents flowing via the cable shields or metal hous- ings. Important The power supply for the TiM3xx and the connected peripheral devices must also guarantee the required level of insulation. Under certain circumstances, a tangible potential can develop between the insulated metal housings and the local ground potential.
4.5.1 Supply voltage connection The TiM3xx requires a supply voltage between DC 10 and 28 V (stabilized protective extra- low voltage) (SELV or PELV) as per the IEC 60364-4-41 standard (VDE 0100 part 410)). The electricity source must be able to provide a power of 5 W at minimum.
Page 20
Switching outputs OUT 1 to OUT 3 signal in combination infringement of the individual fields of a field set (combinatorics table see TiM3xx operating instructions ). Output OUT 4 is used to output an error and a regular index pulse.
Page 23
= max. 32 V D Sub HD * = DC 10 ... 28 V plug, 15-pin *) INGND of the “IN 1 ... IN 4” switching inputs switched to GND of TiM3xx. Not changeable! IN 2 43 IN 2 IN 3...
Page 24
Chapter 4 Techncial Information TiM3xx Detecting Laser Scanner 4.6.5 Wiring the switching outputs in the CDB730-001 Wiring the “OUT 1 ... OUT 4” switching outputs of the TiM3xx in the CDB730-001 connection module Scheme: TiM3xx CDB730-001 Load (e.g. PLC) Shield...
Technical Information Chapter 5 TiM3xx License texts In the product TiM3xx, SICK uses unmodified open source software and, as far as required and permitted in accordance with the relevant license conditions, modified open source software. List of software licenses 1. NCURSES - 5.7- License: Copyright (c) 2006 Free Software Foundation, Inc.