SICK IDM120 Series Quick Start Manual

SICK IDM120 Series Quick Start Manual

Idm corded hand-held scanners
Hide thumbs Also See for IDM120 Series:

Advertisement

QUICK START
IDM Corded
Hand-held Scanners

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IDM120 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for SICK IDM120 Series

  • Page 1 QUICK START IDM Corded Hand-held Scanners...
  • Page 2: How To Use This Guide

    “PROGRAMM”, “Preamble”, “FIN” and then “END” code. SICK makes no warranty of any kind with regard to this publication, including, but not limited to, the implied warranty of merchantability and fitness for any particular purpose. SICK shall not be liable for errors contained herein or for incidental consequential damages in connection with the furnishing, performance, or use of this publication.
  • Page 3: Electrical Specifications

    Scanner description: IDM120 Series IDM140 Series IDM160/260 Series IDM240 Series Power Indicator Beeper Status Indicator Cable Release Hole Trigger Switch Tether Plate Scan Window Lanyard Catch 8015904/YIT8/2015-03-02 © SICK AG · Germany All rights reserved - Subject to change without notice...
  • Page 4 The IDM Set Up Tool is a Windows based configuration software for IDM scanners. You can download the IDM Set up software for free on www.sick.com. For detailed description how to do configuration with IDM Set Up Tool please look at the IDM user guide.
  • Page 5  USB COM Port Emulation The scanner works as a legacy RS232 serial device. You have to install the USB COM software driver (available on www.sick.com) before using. Note: If USB devices are not connected as USB HID (human interface...
  • Page 6 1-15 char. 2-4 digits 1 or 3 char. Variable 1 or 3 char. 1-15 char. 1 char. - Record Suffix - None RETURN ◆ SPACE ENTER 8015904/YIT8/2015-03-02 © SICK AG · Germany All rights reserved - Subject to change without notice...
  • Page 7 The default value is a North American keyboard layout. To change to your desired country please scan one of the codes below. ◆ France Germany United Kingdom-UK Canadian French Spain Spain (Latin America) Nertherlands Japan Sweden/Finland 8015904/YIT8/2015-03-02 © SICK AG · Germany All rights reserved - Subject to change without notice...
  • Page 8 None ◆ SPACE CRLF - Baud Rate – 115.2K BPS 4800 BPS 19.2K BPS 57.6K BPS 2400 BPS 9600 BPS ◆ 38.4 BPS 1200 BPS 8015904/YIT8/2015-03-02 © SICK AG · Germany All rights reserved - Subject to change without notice...
  • Page 9: Data Frame

    & serial trigger) Presentation Mode (scanner turns on when code is presented) Flash Mode (scanner LEDs flash regularly) Force Mode (scanner LEDs are constantly shining) 8015904/YIT8/2015-03-02 © SICK AG · Germany All rights reserved - Subject to change without notice...
  • Page 10: Host Interface Quick Set

    Default”. When scanning “User Default” the scanner will load the configurations that you’ve saved before. Please note when scanning “Master or Factory Default” the user default values will be deleted. 8015904/YIT8/2015-03-02 © SICK AG · Germany All rights reserved - Subject to change without notice...
  • Page 11: Programming Commands

    13. Programming Commands PROGRAM (Enter Programming Mode) (Exit Programming Mode) Option Codes FIN (Finish) 8015904/YIT8/2015-03-02 © SICK AG · Germany All rights reserved - Subject to change without notice...
  • Page 12: Keyboard Interface Control

    Key Pad Emulation Disable key pad emulation ◆ Enable numeric output as key pad output Upper/Lower Case Normal case ◆ Inverse case Upper case Lower case 8015904/YIT8/2015-03-02 © SICK AG · Germany All rights reserved - Subject to change without notice...
  • Page 13: Serial Interface Control

    Scanned Data Suffix ID Postamble Record Suffix 1 char. 1-15 char. 2-4 digits 1 or 3 char. Variable 1 or 3 char. 1-15 char. 1 char. 1 char. 8015904/YIT8/2015-03-02 © SICK AG · Germany All rights reserved - Subject to change without notice...
  • Page 14 2 sec. 3 sec. Hand Free Time-out Short ◆ Medium Long Extremely long Disable Good Read Duration Short Medium ◆ Long Extremely long Extremely short 8015904/YIT8/2015-03-02 © SICK AG · Germany All rights reserved - Subject to change without notice...
  • Page 15: Keyboard Function Code Table

    " & < > Example: ASCII “A”→ HEX “41”; ASCII “a”→ HEX “61” : High Byte of HEX value : Low Byte of HEX value 8015904/YIT8/2015-03-02 © SICK AG · Germany All rights reserved - Subject to change without notice...
  • Page 16 Phone +81 (0)3 5309 2112 Magyarország Phone +36 1 371 2680 Nederland Phone +31 (0)30 229 25 44 Detailed addresses and additional Norge representatives and agencies Phone +47 67 81 50 00 at www.sick.com SICK AG | Waldkirch | Germany | www.sick.com...

This manual is also suitable for:

Idm140 seriesIdm240 seriesIdm160/260 series

Table of Contents