Procom SSU320RHN-GB Owner's Manual page 19

Vent-free gas stove
Hide thumbs Also See for SSU320RHN-GB:
Table of Contents

Advertisement

OBSERVED PROBLEM
Heater produces unwanted odors
Heater shuts off in use (ODS oper -
ates)
Gas odor exists even when heater is
shut off
Gas odor during combustion
Moisture/condensation on windows
TROUBLESHOOTING
Continued
POSSIBLE CAUSE
1. Heater is burning vapors from paint,
hair spray, glues, etc. (See IMPOR -
TANT statement at beginning of
troubleshooting)
2. Gas leak. See WARNING Statement
at beginning of troubleshooting
1. Not enough fresh air is available
2. Low line pressure
3. ODS/pilot is partially clogged
1. Gas leak. See WARNING Statement
at beginning of troubleshooting
1. Foreign matter between control valve
and burner
2. Gas leak. See WARNING Statement
at beginning of troubleshooting
1. Not enough combustion/ventilation air
19
REMEDY
1. Ventilate room. Stop using odor caus -
ing products while heater is running
2. Locate and correct all leaks (see
Checking Gas Connections, Page
9)
1. Open window and/or door for, ven -
tilation
2. Contact local propane/LP gas com -
pany
3. Clean ODS/pilot (see Cleaning Page
14)
1. Locate and correct all leaks (see
Checking Gas Connections, Page
9)
1. Remove foreign matter
2. Locate and correct all leaks (see
Checking Gas Connections, Page
9)
1. Refer to Air for Combustion and Ven -
tilation requirements, Page 5

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SSU320RHN-GB and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

Ssu320rhl-gb