Technical Data - Hamlet Solution Operating & Installation Manual

Table of Contents

Advertisement

TECHNICAL DATA

TECHNICAL DATA
Nominal Heat Output (Kw)
Efficiency Nett (%)
Mean Flue Gas Temperature (c)
Mean CO Emission @ 13% O
Flue Mass Gas Flow (g/s)
Minimum Distance To Combustible
Materials (mm)**
Height (mm)
Width (mm)
Depth (mm) (Inc. Handle)
Height To Centre Of Rear Flue (mm)
Depth From Back To Centre Of Flue
(mm)
Flue Diameter (mm)
Weight Packed (Kg)
Weight Nett (Kg)
8
Hamlet
SOL 5
5.1
74.7
306
²
0.58
(%)
4.4
Rear-625
Sides-525
522
397
388
424
94
102 (4")
57
54
Hamlet
Hamlet
SOL 7
SOL 9
6.1
8.8
72.1
71.6
363
364
0.58
0.68
4.9
6.9
Rear-650
Rear-750
Sides-450
Sides-500
558
600
476
586
386
396
449
485
109
102.5
127 (5")
127 (5")
68
79
64
75
Hamlet Solution Stoves
Hamlet
SOL 11
11
74.7
370
0.71
6.9
Rear-800
Sides-500
605
672
442
478.5
141
152 (6")
106
101

Hide quick links: