7.0 gpm Due to varying water conditions, tank sizes and water pressures, the above settings should be used only as a guideline. D.L.F.C. (Drain Line Flow Control). Backwash and Rapid Rinse Flow Rates. PURE WATER TREATMENT, INC. Tech Support: 1-888-989-7873...
• This installation guide gives a step by step, start to finish procedure for installing PURE TECH 2500 systems using Fleck valves. • Your new system from the PURE WATER TREATMENT, INC. comes with an owner/service manual, which, is enclosed along with these instructions, and will help explain all necessary details required for successful installation and operation of your system.
Assemble all tools needed to install the system, and start your installation! Tools and Materials needed 1) Pipe Cutters 2) PVC Glue 3) PVC, copper or CPVC pipe 4) Two 1” or ¾” male adapters—Depending on which bypass is ordered. PURE WATER TREATMENT, INC. Tech Support: 1-888-989-7873...
Again, doing this before you re-attach them back onto the rear of the valve body assembly. PURE WATER TREATMENT, INC. Tech Support: 1-888-989-7873...
Page 8
LEFT. The conditioned water flowing out from the system, back into your house is always the hole on the RIGHT. PURE WATER TREATMENT, INC. Tech Support: 1-888-989-7873...
When the system is in the backwash mode, water will flow out of this drain line with a fair amount of pressure, especially during the "rapid rinse phases" of the process, and the line may sometimes "jump" a little when changing cycles. PURE WATER TREATMENT, INC. Tech Support: 1-888-989-7873...
8. You now have clean water on your cold water side..The hot water will take a couple of days to become clean, as your hot water tank is full of bad water. PURE WATER TREATMENT, INC. Tech Support: 1-888-989-7873...
Finally, plug the valve in the electrical outlet and set the current time of day. Our sys- tems will regenerate around 2:00am. Check all connections for leaks. 4. You are now ready to experience PURE WATER! Don’t forget to tell your friends, family and neighbors about how excellent the PURE TECH 2500 works for you.
15 minutes. DO NOT put lid or o-rings in the solution. 11. Thoroughly rinse PURE TECH 250 in clean water. 12. Install the PURE TECH 250 back in line and let run for 20 minutes before adding chlorine. PURE WATER TREATMENT, INC. Tech Support: 1-888-989-7873...
Tighten each of the three screws. 7. Push the red button and locate the pointer one more time to ensure the desired regeneration time is correct. 8. Reset the time of day and restore power to the unit. PURE WATER TREATMENT, INC. Tech Support: 1-888-989-7873...
Page 15
Backwash Start-up Procedure Cont. Page 15 How To Set Regeneration Cycle Program: The regeneration cycle program on your water system has been factory preset, however, portions of the cycle or program may be lengthened or shortened in time to suit local conditions. To expose cycle program wheel, grasp timer in upper left- hand corner and pull, releasing snap retainer and swinging timer to the right.
B. Foreign Material in Control. B. Remove Power Head Assembly and Inspect Bore. Remove Foreign Material and Check control in Various Regeneration Positions. C. Internal Control Leak. C. Replace Seals and Piston Assembly. PURE WATER TREATMENT, INC. Tech Support: 1-888-989-7873...
The spacer will be on the end. Pull the center button back, the pins will be retracted and the spacer can be removed from the spacer tool. Fig. 2 Removing Special Tool From Valve Body after Inserting Seal PURE WATER TREATMENT, INC. Tech Support: 1-888-989-7873...
Page 26
20. Replace the two PH screws to hold the back plate to the valve and tighten securely. 21. Connect the brine line form the injector housing to the brine valve (if your unit has timed brine tank fill). 22. Set the time of day dial to the correct time. PURE WATER TREATMENT, INC. Tech Support: 1-888-989-7873...
1) Flow rate control 2) Large 1 1/2” in and out flow 3) Drain to release pressure or clean unit 4) Clearly labeled flow direction 5) Easy replacement of o-ring on lid Figure A PURE WATER TREATMENT, INC. Tech Support: 1-888-989-7873...
Install second ball valve after spigot. This will allow you to stop the water from back feeding from any equipment. DO NOT INSTALL CHLORINE YET. • Go to Page 7 section 5 and continue with installation of PURE TECH 3000si • PURE WATER TREATMENT, INC. Tech Support: 1-888-989-7873...
Chlorine Manufacturers Page 29 Please contact one of these companies to find a dealer near you. Company Phone Number Product OSMONICS 1-800-848-1750 Well Pro Pellets Krudico 1-800-211-1369 Pell-Chlor Better Water Industries 1-507-247-5929 Chlorine Pellets PURE WATER TREATMENT, INC. Tech Support: 1-888-989-7873...
PURE TECH dealer should complete the owner’s registra- ______________________________________________________________________________________ tion form and return one copy to: PURE WATER TREAT- Modification of the Warranty MENT, INC., P.O. Box 730486, Ormond Bch, FL 32173- PURE WATER TREATMENT, INC. does not author- 0486, within 30 days of the installation date.
Need help?
Do you have a question about the PTSF-2510-10 and is the answer not in the manual?
Questions and answers