Backwash Start Up Procedure - Pure Water PTSF-2510-10 Owner's Manual

Pure tech 2500
Table of Contents

Advertisement

How To Set Days On Which Water System Is To Regenerate:
Rotate the skipper wheel until the number "1" is at
the red pointer. Set the days that regeneration is to
occur by sliding tabs on the skipper wheel outward
to expose trip fingers. Each tab is one day. Finger at
red pointer is tonight. Moving clockwise from the
red pointer, extend or retract fingers to obtain the
desired regeneration schedule.
How To Set The Time Of Day:
Press and hold the red button in to disengage the
drive gear. Turn the large gear until the actual time
of day is at the time of day pointer. Release the red
button to again engage the drive gear.
How To Manually Regenerate Your Water
System At Any Time:
Turn the manual regeneration knob clockwise. This
slight movement of the manual regeneration knob
engages the program wheel and starts the regeneration program. The black center knob
will make one revolution in the following approximately three hours and stop in the po-
sition shown in the drawing. Even thought it takes three hours for this center knob to
complete one revolution, the regeneration cycle of your unit might be set only one half
of this time. In any event, conditioned water may be drawn after rinse water stops flow-
ing from the water system drain line.
How to Adjust Regeneration Time:
1. Disconnect the power source.
2. Locate the three screws behind the manual re-
generation knob by pushing the red button in
and rotating the 24 hour dial until each screw
appears in the cut out portion of the manual re-
generation knob.
3. Loosen each screw slightly to release the pres-
sure on the time plate from the 24 hour gear.
4. Locate the regeneration time pointer on the in-
side of the 24 hour dial in the cut out.
5. Turn the time plate so the desired regeneration
time aligns next to the raised arrow.
6. Push the red button in and rotate the 24 hour
dial. Tighten each of the three screws.
7. Push the red button and locate the pointer one
more time to ensure the desired regeneration time is correct.
8. Reset the time of day and restore power to the unit.
Tech Support: 1-888-989-7873