Turn off the main water shutoff valve.
1.
Next, open all plumbing fixtures in the house including all outside faucets in order to
2.
drain the lines of all water possible.
Cut and remove a section of the main incoming water line near where the system is to
3.
be installed. Allowing this line to drain thoroughly.
Install PURE TECH 250. See page 28 for installation
4.
Remove the yoke (or optional bypass valve) from the back of the tank valve by loos-
5.
ening the two small stainless steel clamps on either side of the rear valve assembly,
that holds it in place. Then simply pull it off the back of the valve. Now that you have
the yoke or bypass valve removed, follow the directions below to make them ready to
install on the valve.
INSTRUCTIONS FOR USING A YOKE. If you have a standard Noryl Plastic yoke,
6.
it will have two ¾" or 1" male thread nipples, (one inlet & one outlet). You will need
to buy two ¾" or 1" Female thread adapters to whatever type and size of piping you
are plumbing the system to.
INSTRUCTIONS FOR USING A BYPASS. If you are using our optional ¾" or 1"
7.
brass bypass valve, you will need to purchase two ¾" or 1" Male thread adapters to
whatever type and size pipe you are plumbing to.
If you are going to use copper piping and be soldering joints, we do not recommend
8.
applying intense heat, to your new valve/meter assembly. We always recommend that
you remove the yoke or bypass from the valve assembly, and attach your plumbing
adapters to the yoke or bypass away from the valve. This simple step will ensure that
you are not applying any heat as you solder or pressure as you tighten the adapters
onto the yoke/bypass, while they are mounted on the valve body itself.
Another tip if you are using copper adapters. Always solder a 3" to 5" piece of copper
9.
pipe into each of the two pipe adapters away from the valve, then let them cool off
before threading each one onto the yoke or bypass valve.
After they cool off, apply Teflon tape to the male threads of the Noryl yoke, (or onto
10.
the male adapters for the brass bypass valve), and securely tighten them to the yoke or
bypass valve. Again, doing this before you re-attach them back onto the rear of the
valve body assembly.
Tech Support: 1-888-989-7873