Airwell AWSI YIFA060–H13 Service Manual page 20

Table of Contents

Advertisement

Auto wind control
When unit is set to auto wind by remote controller or wired controller, indoor wind speed will be
controlled abide by regulation as follow
a) If TA - TS≥4℃, at high speed
b) If TS +3℃≤TA<TS +4℃, at medium speed c) If TS +2℃≤TA<TS +3℃, at low speed
d) If TS≤TA<TS +2℃, at low speed intermittently
e) If TA<TS, the indoor fan will restart after stop for 3 min, and operates at low wind.
Ventilation operation
Outdoor unit stay closed, indoor fan motor operates at set wind and wind speed can be set at high, medium, low by remote
controller.
Heating operation
Temperature is set by remote controller (or wired controller), temperature control range from 16℃- 32℃, user can adjust
temperature through "temperature + "and "temperature -" button on remote controller or wired controller. Press "fan speed" button to
choose fan speed among auto wind, high speed wind, medium speed wind, low speed wind.
Operation state
a) When TA- TS≤-1℃, if compressor meets 3 min protection, the compressor and outdoor fan start, indoor fan runs according to
Anti-cold air condition
b) When TA- TS≥1℃, if compressor meets 3 min continuous operation, the compressor and outdoor fan stop, indoor fan runs
according to Anti-cold air condition
c) If TA=TS, stay in the previous state.
CONTROL SYSTEM
19 | S e r v i c e M a n u a l

Advertisement

Table of Contents
loading

This manual is also suitable for:

Faf 060 – n11

Table of Contents