Technical data

Temperature range
Operating voltage
Switching capacity
Switch
Hysteresis
Ambient temperature
Protection class
Sensor type
Sensor
LED indicator:
No light
Red
Green
8
-10°C - +50°C
180 - 250 V ~ 50 Hz
Cos φ = 0 .3 max . 4 A
10 A
± 0 .2°C
-30°C to +55°C
IP 44
NTC
-10°C
66 kOhm
0°C
42 kOhm
+25°C
15 kOhm
+50°C
6 kOhm
System is OFF .
System is OFF .
Heating is ON, but the set temperature has not
been reached .
Set temperature is reached and the heating is
turned off .
VIFZK102