9.
technIcal data
Mains voltage
3~50/60 Hz
Rated power
80 % ED
100 % ED
Connection cable/
fuse delayed
Max. welding voltage 40
70 % ED
80 % ED
100 % ED
Max. welding voltage 20
100 % ED
Welding current range
MMA
TIG
MIG
Max. welding voltage
Open circuit voltage
Open circuit power
Efficiency
at nominal values
Power factor
at nominal values
Storage temperature
range
Operating
temperature range
Temperature class
Degree of protection
Extemal dimensions
length
width
height
Weight
Voltage supply for
auxiliary devices
X 14, X 15
Voltage supply for cooling unit
PROCOOL 10
X 16
14 – Kemppi pro evolution 300, 400, 500, 300 mvu, 400 mvu, 500 mvu / 0617
Pro Evolution 3200
400 V -15%...+20%
320 A / 13,3 kVA
4 x 6 S - 5 m / 25 A
C
0
320 A / 32,8 V
C
0
320 A / 32,8 V
10 A ... 320 A
5 A ... 320 A
12 V ... 37 V
46 V / 300 A
appr. 65 V
< 75 W
appr. 85 %
appr. 0,93
-40 ... +60
C
0
-20 ... +40
C
0
H (180
C) / B (130
C)
0
0
IP 23 C
530 mm
230 mm
520 mm
37 kg
50 V DC
fuse 6,3 A delayed
1~, 230 V / 250 VA
fuse 1,0 A delayed
Pro Evolution 4200
400 V -15%...+20%
420 A / 19,7 kVA
400 A / 18,6 kVA
4 x 6S - 5 m /35 A
420 A / 36,8 V
400 A / 36 V
420 A / 36,8 V
10 A ... 420 A
5 A ... 420 A
12 V ... 39 V
46 V / 400 A
appr. 65 V
< 75 W
appr. 85 %
appr. 0,93
-40 ... +60
C
0
-20 ... +40
C
0
H (180
C) / B (130
C)
0
0
IP 23 C
530 mm
230 mm
520 mm
41 kg
50 V DC
fuse 6,3 A delayed
1~, 230 V / 250 VA
fuse 1,0 A delayed
Pro Evolution 5200
400 V -15%...+20%
520 A / 26,6 kVA
440 A / 20,0 kVA
4 x 6S - 5 m / 35 A
520 A / 40,0 V
440 A / 37,6 V
480 A / 39,6 V
10 A ... 520 A
5 A ... 520 A
12 V ... 42 V
50 V / 500 A
appr. 65 V
< 75 W
appr. 85 %
appr. 0,93
-40 ... +60
C
0
-20 ... +40
C
0
H (180
C) / B (130
C)
0
0
IP 23 C
530 mm
230 mm
520 mm
48 kg
50 V DC
fuse 6,3 A delayed
1~, 230 V / 250 VA
fuse 1,0 A delayed
© Kemppi oy