Install indoor unit

1.Always mount the rear panel horizontally. Due to the water tray of indoor unit has been adopted the
both-way drainage design, the outlet of water tray should be adjusted slightly down when installing, that is
taking the outlet of the water tray as the center of a circle, the included angle between the evaporator and
level should be 0 or more, that is good for condensing water drainage.
2.Fix the rear panel on the wall with screws.
(Where is pre-covered with plastic granula)
3.Be sure that the rear panel has been fixed
firmly enough to withstand the weight of an
adult of 60kg, further more, the weight should
be evenly shared by each screw.
1.Make the piping hole (Ф55) in the wall at a slight downward slant to the
outdoor side.
2.Insert the piping-hole sleeve into the hole to prevent the connection piping
and wiring from being damaged when passing through the hole.
1.For well draining, the drain hose should be placed at a downward slant.
2.Do not wrench or bend the drain hose or flood its end by water.
3.When the long drainage hose passing through indoor,
should wrap the insulation materials.
1.Open the surface panel.
2.Remove the wiring cover Fig6, and then take off wire clamp.
3.Route the power connection cord from the back of the indoor unit and pull it toward the front
through the wiring hole for connection.
4.Connect the power connection cord to the terminal block, and then fix the cord with wire clamp.
5.Reassemble the clamp and the wiring cover.
6.Recover the surface panel.
Install the rear panel
Install the piping hole
Install the water drainage pipe
Connect indoor and outdoor electric wires
Wall
Mark on the middle of it
Space
to the
wall
150 m
m
above
Left
Φ55mm
(Rear piping hole)
N(1) 2
3
blue black brown
21
Gradienter
Fig.5
Indoor
Wall pipe
Wrenched
yellow-
green
Fig.6
Wall
Space
to the
wall
150 m
m
above
Right
Φ55mm
(Rear piping hole)
Outdoor
Seal pad
Φ55
Bent
Flooded