Installation of Indoor Unit

1. Mounting plate should be installed horizontally. As the water tray's outlet for the indoor unit is two-way
type, during installation, the indoor unit should slightly slant to water tray's outlet for smooth drainage of
condenser water.
2. Fix the mounting plate on the wall with screws.
3. Be sure that the mounting plate has been fixed firmly enough to withstand about 60 kg. Meanwhile, the
weight should be evenly shared by every screw.
09K TA UNIT:
146
Φ55
35
135
18K UNIT:
189
281
Φ
70
55
150
94
90
1.Slant the piping hole (Φ55 / Φ70) on the wall slightly downward to the
outdoor side.
2.Insert the piping-hole sleeve into the hole to prevent the connection piping
and wiring from being damaged when passing through the hole.
Connect the drain hose to the outlet pipe of the indoor unit.
1.
Bind the joint with rubber belt.
2.
Put the drain hose into insulating tube.
3.
Wrap the insulating tube with wide rubber belt to prevent
the shift of insulating tube. Slant the drain
slightly for smooth drainage of condensing water.
Note: The insulating tube should be connected reliably with
the sleeve outside the outlet pipe. The drain hose should be
slanted downward slightly, without distortion, bulge or
fluctuation. Do not put the outlet in the water.
Installation of Mounting Plate
846
156
254
Φ55
34.5
60
685
144
575
185
319
Φ
70
55
13
55
130
69
90
1018
Drill Piping Hole

Installation of Drain Hose

09
12K TB UNIT:
Φ 55
160
24
28K UNIT:
outlet pipe of
indoor unit
hose
downward
25
Φ 55
35
80
Outdoor
Indoor
Wall pipe
Seal pad
Fig.5
drain hose
rubber belt
outlet pipe of
drain hose
indoor unit
rubber belt
insulating tube
rubber belt
outlet pipe of
indoor unit
insulating tube
connected
distortion
bulge
Flooded
Φ55/Φ70
outlet pipe of
indoor unit

Advertisement