Download Print this page

Denon ADV-1000 Service Manual page 27

Dvd
Hide thumbs Also See for ADV-1000:

Advertisement

QQ
3 7 63 1515 0
Pin No.
Pin Name
156
Vss
157
Vcc
158
HA 2
159
VPP
160
AUX 0
161
AUX 1
162
AUX 2
163
Vss
164
Vcc
165
AUX 3
166
AUX 4
167
AUX 5
168
AUX 6
169
AUX 7
170
LOE#
171
Vss
172
Vcc
173
LCS 0#
174
LCS 1#
175
LCS 2#
176
LCS 3#
177
Vss
178
LD 0
179
LD 1
TE
L 13942296513
180
LD 2
181
LD 3
182
LD 4
183
Vcc
184
Vss
185
LD 5
186
LD 6
187
LD 7
188
LD 8
189
LD 9
190
LD 10
191
LD 11
192
Vss
193
Vcc
194
LD 12
195
LD 13
196
LD 14
197
LD 15
198
LWRLL#
199
LWRHL#
200
Vss
201
Vcc
202
NC
www
203
NC
204
LA 0
205
LA 1
.
206
LA 2
207
LA 3
208
Vss
http://www.xiaoyu163.com
I/O
Function
I
GND
I
3.6V power supply
I/O
Host address bus
I
Peripheral protection voltage
I/O
Auxiliary port, (SDATA) I/O
I/O
Auxiliary port, (SCLK) O
I/O
Auxiliary port, (VFD DATA) I/O
I
GND
I
3.6V power supply
I/O
Auxiliary port, (AMUTE) O
I/O
Auxiliary port, (IR) I
I/O
Auxiliary port, (POWER) I
I/O
Auxiliary port, (VFDCS) O
I/O
Auxiliary port, (VFDCLK) O
O
Device output enable, active low
I
GND
I
3.6V power supply
O
Chip select [0], active low
O
Chip select [1], active low
O
Chip select [2], active low
O
Chip select [3], active low
I
GND
I/O
Device data bus
I/O
Device data bus
I/O
Device data bus
I/O
Device data bus
I/O
Device data bus
I
3.6V power supply
I
GND
I/O
Device data bus
I/O
Device data bus
I/O
Device data bus
I/O
Device data bus
I/O
Device data bus
I/O
Device data bus
I/O
Device data bus
I
GND
I
3.6V power supply
I/O
Device data bus
I/O
Device data bus
I/O
Device data bus
I/O
Device data bus
O
Device write enable, active low
O
Device write enable, active low
I
GND
I
3.6V power supply
No connect pin
No connect pin
x
ao
O
Device address output
y
O
Device address output
i
O
Device address output
O
Device address output
I
GND
http://www.xiaoyu163.com
8
TP2050 (AP: IC102, 202, 302)
VCCSIGN
VCCSIGN
VSS
VSS
IN2B
IN2A
IN1B
IN1A
TH_WAR
FAULT
TRISTATE
PWRDN
CONFIG
IBIAS
VDD
VDD
GNDREG
GNDCLEAN
TP2050 Terminal Function
Pin
Function
1
GNDSUB
Q Q
2,3
OUT2B
3
6 7
1 3
4
VCC2B
5
GND2B
6
GND2A
7
VCC2A
8,9
OUT2A
10,11
OUT1B
12
VCC1B
13
GND1B
14
GND1A
15
VCC1A
16,17
OUT1A
18
19
GNDCLEAN
20
GNDREG
21,22
23
24
CONFIG
25
PWRDN
26
TRISTATE
27
FAULT
28
TH_WAR
29
30
31
32
33,34
35,36
VCCSIGN
u163
.
2 9
9 4
2 8
36
1
35
2
34
3
33
4
32
5
31
6
30
7
29
8
28
9
27
10
26
11
25
12
24
13
23
14
22
15
21
16
20
17
19
18
Description
Substrate ground
Output half bridge 2B
1 5
0 5
8
2 9
9 4
Positive supply
Negative supply
Negative supply
Positive supply
Output half bridge 2A
Output half bridge 1B
Positive supply
Negative supply
Negative supply
Positive supply
Output half bridge 1A
NC
Not connected
Logic ground
Ground for Vdd regulator
VDD
5V regulator referenced to ground
IBIAS
Logic high voltage
Config input
Stand-by pin
Hi-Z pin
Fault output
Thermal warning output
IN1A
Input half bridge 1A
IN1B
Input half bridge 1B
IN2A
Input half bridge 2A
IN2B
Input half bridge 2B
m
VSS
5V regulator referenced to Vcc
Signal positive supply
co
ADV-1000
9 9
GNDSUB
OUT2B
OUT2B
VCC2B
GND2B
GND2A
VCC2A
OUT2A
OUT2A
OUT1B
OUT1B
VCC1B
GND1B
GND1A
VCC1A
OUT1A
OUT1A
NC
2 8
9 9
27

Advertisement

loading