PEAK METER

The peak meters always show the incoming audio signal, no matter if the channel is recorded or not as
long as a source is selected.
Actively recorded channels are drawn with a lighter outline and the channel indicator left of the peak
meter will be green.
The peak meters are updated 12 times per second with the maximum signal from the last 1/12 of a
second period. In case the input signal exceeds 19dBu the whole bar will be filled with red.
The total range of the peak meter is -36 dB to 20dB. (Values below 0 dB are shown with half resolution)
For reference the following markers are supplied on the peak meter: Solid marker at 0 dB, Dashed
marker at 4,10,14,18 dB.
Channel 1/2 enabled for recording, channel 1 around 5 dB, channel 2 clipping.