TABLE 6: DM 300 COOLING CAPACITIES (25 TON)
AIR ON
EVAPORATOR
COIL
TOTAL
POWER
1
CAP.
INPUT
WB
MBH
KW
CFM
°F
72
371
27.1
67
340
26.1
12000
62
329
25.5
57
329
25.5
72
365
27.0
67
336
25.9
11000
62
324
25.3
57
324
25.3
72
359
26.8
67
332
25.7
10000
62
318
25.2
57
318
25.1
72
354
26.6
67
326
25.5
9000
62
314
25.0
57
314
25.0
72
349
26.4
67
321
25.3
8000
62
310
24.8
57
310
24.8
72
318
25.2
67
290
24.0
6000
62
282
23.7
57
282
23.7
AIR ON
EVAPORATOR
COIL
TOTAL
POWER
1
CAP.
INPUT
WB
MBH
KW
CFM
°F
72
337
30.7
67
310
29.5
12000
62
300
28.8
57
299
28.8
72
331
30.5
67
306
29.3
11000
62
295
28.5
57
294
28.5
72
326
30.2
67
302
29.0
10000
62
290
28.3
57
290
28.2
72
322
30.0
67
297
28.8
9000
62
286
28.1
57
286
28.1
72
319
29.8
67
293
28.6
8000
62
283
28.0
57
283
28.0
72
290
28.3
67
264
26.9
6000
62
258
26.6
57
258
26.6
1. These capacities are gross ratings. For net capacity, deduct the heat of the supply air blower motor, MBH = 3.415 x KW. Refer to the appropriate
Blower Performance Table for the KW of the supply air blower motor.
2. These ratings include the condenser fan motors (Total 2.3 KW) and the compressor motors but not the supply air blower motor.
Nominal Rating
18
TEMPERATURE OF AIR ON CONDENSER COIL
85°F
SENSIBLE CAPACITY
ENTERING DRY BULB, °F
2
86
83
80
77
74
277
240
203
167
130
335
299
262
226
189
329
329
329
293
256
329
329
329
292
256
260
226
193
159
125
317
283
249
216
182
324
324
313
279
245
324
324
315
281
247
244
213
182
151
120
298
268
237
206
175
318
318
296
265
235
318
318
301
270
239
229
201
173
145
117
280
252
224
196
168
314
306
282
254
226
314
308
286
258
230
215
190
165
140
115
262
237
212
187
162
310
293
268
243
218
310
297
272
247
222
186
167
148
129
110
226
206
187
168
149
277
258
240
221
201
281
262
243
224
205
TEMPERATURE OF AIR ON CONDENSER COIL
105°F
SENSIBLE CAPACITY
ENTERING DRY BULB, °F
2
86
83
80
77
74
264
228
191
155
118
309
283
246
210
173
300
300
300
263
226
299
299
299
263
226
254
221
187
153
119
302
276
242
208
174
295
295
294
260
226
294
294
294
261
227
244
213
183
152
121
294
268
237
206
176
290
290
287
256
226
290
290
290
259
228
228
200
172
144
116
276
251
223
195
167
286
284
271
243
215
286
285
273
245
217
212
187
162
137
112
259
234
209
184
159
283
278
255
230
205
283
280
257
232
207
180
161
141
122
103
224
200
181
162
142
258
241
223
204
184
258
242
224
205
186
1
, MBH
TOTAL
POWER
1
CAP.
INPUT
MBH
KW
71
68
-
-
354
28.8
152
116
325
27.7
219
183
315
27.1
219
183
314
27.1
-
-
348
28.6
148
114
321
27.5
212
178
309
26.9
214
180
309
26.9
-
-
342
28.5
144
113
317
27.4
204
173
304
26.8
208
177
304
26.7
-
-
338
28.2
141
113
312
27.1
198
170
300
26.5
203
175
300
26.5
-
-
334
28.0
137
112
307
26.9
193
168
297
26.3
197
172
297
26.3
-
-
304
26.8
130
111
277
25.5
192
163
270
25.2
186
167
270
25.2
1
, MBH
TOTAL
POWER
1
CAP.
INPUT
MBH
KW
71
68
-
-
320
32.6
137
100
294
31.3
190
153
285
30.5
190
153
285
30.5
-
-
315
32.3
141
107
291
31.0
192
159
280
30.3
193
160
280
30.3
-
-
310
32.1
145
114
287
30.8
195
164
276
30.0
197
166
275
29.9
-
-
306
31.8
139
111
283
30.5
187
159
272
29.8
189
161
272
29.7
-
-
303
31.6
134
109
278
30.3
180
155
269
29.6
182
157
269
29.6
-
-
276
30.0
123
104
251
28.5
165
146
245
28.2
167
148
245
28.2
036-21476-002-E-0904
95°F
SENSIBLE CAPACITY
ENTERING DRY BULB, °F
2
86
83
80
77
74
268
231
195
158
122
324
288
251
214
178
315
315
315
278
241
314
314
314
278
241
257
223
189
155
122
312
279
245
211
178
309
309
307
273
239
309
309
309
275
242
245
214
184
153
122
301
270
239
208
177
304
304
299
268
237
304
304
304
273
242
228
200
172
144
116
279
251
223
195
167
300
295
280
253
225
300
297
285
257
229
211
186
161
136
111
257
232
207
182
157
297
287
262
237
212
297
291
266
241
216
177
158
138
119
100
213
194
175
156
137
262
243
225
206
187
266
247
228
209
190
115°F
SENSIBLE CAPACITY
ENTERING DRY BULB, °F
2
86
83
80
77
74
261
224
188
151
114
294
278
242
205
169
285
285
285
248
212
285
285
285
248
211
252
218
185
151
117
291
273
239
205
171
280
280
280
246
213
280
280
280
246
213
243
212
181
151
120
287
267
236
205
174
276
276
276
245
214
275
275
275
244
214
228
200
172
144
116
274
251
223
195
167
272
272
262
234
206
272
272
261
234
206
213
188
163
138
113
260
235
210
185
160
269
269
248
223
198
269
269
248
223
198
183
164
145
125
106
222
203
194
165
146
245
239
220
201
182
245
240
221
202
182
Unitary Products Group
1
, MBH
71
68
-
-
141
105
205
168
205
168
-
-
144
110
206
172
208
174
-
-
146
115
207
176
211
180
-
-
139
111
197
169
201
173
-
-
132
107
187
162
191
166
-
-
118
99
167
148
171
152
1
, MBH
71
68
-
-
132
95
175
138
175
138
-
-
138
104
179
145
179
145
-
-
143
112
183
152
183
152
-
-
139
111
178
150
178
150
-
-
135
110
173
148
173
148
-
-
127
108
163
144
163
144

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sunline 2000 dm 240 seriesSunline 2000 dm 300 series

Table of Contents