7.
To remove the recirculation pump:
a) Loosen the clamps and pull the recir-
culation hoses off the pump. Note that
there is a tab on the outlet connector
that fits into a slot in the hose.
b) Remove the three 5/16˝ hex-head
screws from the recirculation pump
and remove the pump from the tub.
c) Disconnect the 2-wire connector from
the recirculation pump terminals.
Slide Pump Hose
Onto Connector With
Tab Into Hose Slot
Inlet Hose
Recirculation Pump Screws
4-13
Outlet Hose
Wire Connector