8.13 Model Assembly (MA) Test Mode Test

Model Assembly Test Mode is an embedded series of operational tests of the unit's user interface and
functional features.
Motorola iDEN recommends MA Test Mode be performed after any servicing of the unit.
An audio test cable is required to complete MA Test Mode effectively. See the Required Tools section
or contact Motorola's Aftermarket Accessories Division (AAD).
MA Test mode is achieved by starting from a power-down condition:
1. Press and hold three number keys simultaneously with the Power key, such as 1-2-3, 4-5-6,
7-8-9.
2. Release once the opening screen appears in the main display.
3. Follow instructions as they appear pressing the indicated keys.
4. No instruction? Press any key or Scroll right.
5. No reaction? Power down the unit and start MA Test again.
Main LCD and CID displays depicted as follows. Note that opening displays may vary depending on
carrier preference. The i760 MA Test excludes the Digital Camera Test:
68P80400P94-O
FIELD LEVEL TEST MODES AND PROCEDURES: Model Assembly (MA) Test Mode Test