I850 Camera Test - Motorola iDen i850 Field Service Manual

Digital multi-service, data-capable portable
Hide thumbs Also See for iDen i850:
Table of Contents

Advertisement

FIELD LEVEL TEST MODES AND PROCEDURES: i850 Camera Test
8.15

i850 Camera Test

Use this test to check camera module. Symptoms: Bad view finder (noise, poor color,
synchronization error).
Power up
the unit.
Enter the
Model Assembly
(MA) Test Mode.
Verify
that the viewfinder
shows the captured
image correctly.
Pass
Unit passed test. Look for
system, coverage, accessory,
or software problems.
8-16
Fail
Replace
Flip Assembly
and repeat the
test.
Pass
Fail
Replace
Fail
the main FPC
and repeat the
test.
Pass
Replace
the main
board.
68P80400P94-O