Motorola iDen i850 Field Service Manual page 106

Digital multi-service, data-capable portable
Hide thumbs Also See for iDen i850:
Table of Contents

Advertisement

: MECHANICAL PARTS REWORK PROCEDURE
Top 330ºC - No Bottom Heat
OK Industries 151/min
Pace
Always protect switches from heat and Flux intrusion to avoid component malfunction.
6-10
6/7
ORIENTATION
Use Liquid Flux Indium-Indalloy NC771 ONLY.
Use Flux Sparingly.
N-Q07
"I" over nearby SW during Removal
Procedure.
"I" over nearby SW & "A" over LED
during Installation Procedure.
NOTE

Advertisement

Table of Contents
loading

This manual is also suitable for:

Iden i760

Table of Contents