Connect The Gas Supply Line; Install Log Set - Vermont Castings 0003380 Installation And Operating Instructions Manual

Radiance vent free gas heater
Table of Contents

Advertisement

Radiance
Vent-Free Gas Heater
®

Connect the Gas Supply Line

Check the Rating Plate attached by a steel cable to the
firebox, to confirm that you have the appropriate firebox for
the type of fuel to be used.
This appliance should only be connected by a qualified
gas technician. Test to confirm manifold pressures as
specified below.
The Radiance Heater and its individual shutoff valve
must be disconnected from the gas supply piping during
any pressure testing of that system at test pressures in
excess of 1/2 psig (3.5 kPa).
The Radiance Heater must be isolated from the gas
supply piping system by closing its individual manual
shutoff valve during any pressure testing of the gas
supply piping system at test pressure equal to or less
than 1/2 psig.
There must be a gas shutoff between the stove and the
supply.
In order to connect Natural Gas, use a fitting with 3/8"
NPT nipple on the valve side and 1/2" natural gas supply
line with an input of 35,000 BTUs at a manifold pressure
of 3.5" and minimum inlet supply for adjustment of 5.5"
w.c.
In order to connect Propane, use a fitting with 3/8" NPT
nipple on the valve side and 1/2" propane gas supply
line with an input of 35,000 BTUs at a manifold pressure
of 11.0" and minimum inlet supply for adjustment of
11.0" w.c.
Gas connection should be made in accordance with
current National Fuel Gas Code, ANSI Z223.1. Since some
municipalities have additional local codes, be sure to consult
you local authority.
Connect the gas supply and test for leaks. Use a 50/50
solution of liquid soap and water to test for leaks at gas fittings
and joints. NEVER test with an open flame. Light the pilot
according to the directions in the Lighting and Operating
section of this manual, before going to the next step.
13
!
This appliance should only be connected by a
qualified gas technician. Test to confirm manifold
pressures as specified below.
The Radiance Heater and its individual shutoff valve
must be disconnected from the gas supply piping
during any pressure testing of that system at test
pressures in excess of 1/2 psig (3.5 kPa).
The Radiance Heater must be isolated from the gas
supply piping system by closing its individual manual
shutoff valve during any pressure testing of the gas
supply piping system at test pressure equal to or less
than 1/2 psig.
There must be a gas shutoff between the stove and
the supply.
In order to connect Natural Gas, use a fitting with 3/8"
NPT on the valve side and 1/2" natural gas supply line
with an input of 35,000 Btus at a manifold pressure of
3.5" between minimum inlet supply of 5.5" w.c. and
maximum of 14.0" w.c.
In order to connect Propane, use a fitting with 3/8" NPT
on the valve side and 1/2" propane gas supply line with
an input of 35,000 Btus at a manifold pressure of 11.0"
between a minimum inlet supply of 11.0" w.c. and
maximum of 14.0" w.c.

Install Log Set

1. Remove the logs from their packaging, and inspect each
piece for damage. DO NOT INSTALL DAMAGED LOGS.
2. Install the rear left log by placing it on the sheet metal shelf
at the back of the firebox. (Fig. 22) The log should touch
the back wall of the firebox. Slide the log to the left until
the left side lines up with the left bracket. (Fig. 22) When
the log is in place the left front corner of the log should
rest on the decorative grate.
3. Install the rear right log by placing it on the sheet metal
shelf at the back toward the right. Make sure the right side
of the log lines up with the right bracket. (Fig. 22) NOTE:
When the right and left rear logs are in place, they should
touch the back of the firebox and each other.
4. Install the right log by engaging hole on the bottom with
pin on the right rear log. (Fig. 22) Set the bottom of the
log on the bracket and bring forward to come in contact
with decorative grate on right.
CAUTION